Delivery
.
open
Commissioning Manager
Delivery
Own the last 20% of every project.
Wacol + SEQ sites
Northern NSW sites too. On call 1 in 4 in energisation campaigns.
Full-time, permanent
$185,000 to $215,000 plus 12% super.
Senior, 10 or more years
We test whether the candidate has personally energised above 33 kV and will make the go or no-go call in front of a client.
Own the last 20% of every project, the part that sets the energisation date. At Kestrel Power you join at award, review designs for testability and sign the readiness review 30 days out. Your commissioning team energises 33 kV to 132 kV substations on the contracted date. $185,000 to $215,000 plus super. Wacol, Brisbane, with sites across South East Queensland.
Purpose
- The Commissioning Manager owns the last 20% of every project, which decides the energisation date. You join each project at award, review designs for testability, plan the test and energisation sequence, and sign the readiness review. Your team energises on the contracted date, or tells the client at least 30 days ahead why it will not.
Responsibilities
- Join every project at award and review designs for testability, test access and sequence before design freeze.
- Write commissioning plans, inspection and test plans and energisation switching programs for network approval.
- Lead the commissioning team of test technicians and commissioning engineers, rostered to project need.
- Run pre-commissioning, site acceptance testing, primary and secondary injection and protection functional testing.
- Chair the energisation readiness review 30 days before energisation and issue a written go or no-go.
- Manage the network approvals tracker with the Network Service Provider and report weekly to the client.
- Direct energisation on the day as Kestrel's senior authority and coordinate with the network control room.
- Own test records, settings files and punch-list closure, and deliver the commissioning data pack at handover.
- Own the calibration register and allocate test equipment across projects.
- Mentor commissioning leads and sign off test technician competencies and HV authorisations.
Essential criteria
- Queensland Electrical Mechanic licence, or an electrical engineering degree with RPEQ.
- Ten or more years in HV commissioning, at least five as lead on 33 kV to 132 kV works.
- Led energisation of at least three substations above 33 kV.
- Current ESI worker card and an HV switching authorisation recognised by Powerlink or Energex.
- Working knowledge of AS 2067, ENA Doc 001 and network switching and permit-to-work rules.
- Hands-on use of primary injection sets, relay test sets (Omicron or equivalent), VLF and partial discharge testing.
- White card, Queensland C-class licence, current first aid, LV and HV rescue.
- Permanent Australian work rights.
Desirable criteria
- Data centre energisation experience including UPS and generator interfaces.
- IEC 61850 commissioning experience.
- Prior employment with Powerlink, Energex, Ergon Energy or a tier-one ESI contractor.
- Cert IV in Training and Assessment.
- GIS commissioning experience at 66 kV or above.
First 90 days
- Days 1 to 30: complete ESI inductions, audit test equipment and the calibration register, review commissioning plans for two live projects.
- Days 31 to 60: assign a commissioning lead to each project, hold the first readiness review, set up digital test records.
- Days 61 to 90: recruit two test technicians, complete one energisation or a readiness review at T minus 30 days, issue the commissioning data pack template.
Success measures
- 100% of readiness reviews held at least 30 days before energisation.
- At least 90% of energisations within one business day of the contracted date, excluding network-caused delay.
- Fewer than 20 open defects at handover and zero lost-time injuries in the commissioning team.
Screening questions
- List the three largest substations you have energised: voltage, MVA, your role, and the date against plan.
- What was your worst energisation-day problem, and what did you do in the first hour?
- What evidence do you need on the table before you sign a go decision at a readiness review?
- Which relay platforms and test sets have you personally operated?
- What is your current HV switching authorisation, and with which network?
Package and conditions
- Reports to: Managing Director.
- Salary band: $185,000 to $215,000 plus 12% superannuation.
- Award: Professional Employees Award MA000065, Level 4 to Level 5 benchmark, annualised salary paid above award.
- Location and roster: Wacol depot and project sites across South East Queensland and northern New South Wales. Monday to Friday, 38 hours plus reasonable additional hours; on-call 1 in 4 during energisation campaigns; shutdown weekends by roster.
- Employment type: Permanent, full-time.
- How to apply: use the Apply button to open the Kestrel careers portal, answer the five screening questions and attach your CV and tickets. Questions go to [email protected]. Kestrel Power starts trading on 4 January 2027; start dates are agreed with each successful candidate.
open role
Commissioning Manager
reports to
Managing Director
location
Wacol + SEQ sites
type
Full-time, permanent
band
$185k – $215k
super
12% on top

apply
A person reads every application.
No cover letter required. Start with your email, then answer five screening questions in the portal.
hiring now
Engineering
3 open
Delivery and field
5 open
Safety and support
2 open

